PERFORMANCE Input Range, rad/sec2 (Note 1) ± 200 ± 500 ± 1000 Full Range Output (FRO), volts ± 1.0% ± 5.0 ± 5.0 ± 5.0 Non Linearity (%FRO) Max. (Note 2) 0.50 0.20 0.10 Scale Factor, volts/rad/sec2, Nominal 0.025 0.010 0.005 Scale Factor Temp Sens (PPM/°C, Max.) 180 180 180 Bias, rad/sec2, Max. 1.0 4.0 4.0 Bias Temp Sens, rad/sec2/°C, Max. 0.05 0.05 0.10 Natural Frequency, Hz, Nominal (Note 3) 70 100 120 Bandwidth (-3db), Hz, Nominal 70 100 120 Input-Axis Misalignment, ° Max. 1.0 1.0 1.0 Resolution and Threshold, rad/sec2, Max. 0.005 0.005 0.005 ELECTRICAL Input Voltage, VDC, Nominal (Note 4) Input Current mA, Nominal Output Impendance, ohms, Nominal 10.0k 4.0k 5.0k Noise, Mv RMS Max. ENVIRONMENTAL Temp Range, Operating Temp Range, Survival Shock Seal Weight 3.0 oz. [85.049g] Notes: 1 - Full range is defined as "from negative full input acceleration to positive full input acceleration." 2 - Nonlinearity is specified as deviation of output referenced to a best fit straight line, independent of misalignment. 3 - Output phase angle = -90°. 4 - Unit Power connections can be easily adapted for operation from single-ended, floating power supplies of 24 to 36 Volts DC